Flame Retardant CAT6 Data Cables LSZH Sheath
Delivery term:The date of payment from buyers deliver within days-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Shandong
-
Validity to:
Long-term effective
-
Last update:
2017-07-04 00:10
-
Browse the number:
340
+
- Contactaixin:
Contactaixin:
sdhuanyu(Mr.)
- Email: telephone: phone:
-
Area:
Shandong
Address:1building, Shuntai Square, High-Tech Zone, Jinan City, China
- Website:
+
Supplying you with customized flame retardant cat6 data cables lszh sheath, it is one of the reliable flame retardant cat6 data cables lszh sheath manufacturers and suppliers, welcome to wholesale our products at good price from our factory.
Flame Retardant CAT6 Data Cables
Application: |
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables are with copper wire braid armoured & flame retardant mud resistant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable. |
Standard: |
Basic design to EN50173 |
FIRE PERFORMANCE
Flame Retardance (Single Vertical Wire Test) |
EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) |
EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free |
IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1* |
No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2* |
minimum Smoke Emission |
IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases |
NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
VOLTAGE RATING
60V
CABLE CONSTRUCTION
Conductors: 23AWG solid bare copper.
Insulation: HDPE.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655:section 2.6 can be offered.)
Cat6 F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.
Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.
Physical AND THERMAL PROPERTIES
Temperature range: -30°C ~ +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (fixed state): 4 x Overall Diameter
Electrical Properties
AWG |
23 |
|
Nominal Conductor Diameter |
mm |
0.56/0.57 |
maximum DC Resistant@20°C |
Ω/100m |
9.38 |
maximum DCR Unbalance |
% |
3 |
maximum mutual Capacitance |
pF/m |
5.8 |
maximum Capacitance Unbalance |
pF/100m |
30 |
Characteristic Impedance@1-100mHz |
Ω |
100+/-15 |
maximum Propagation Delay Skew |
ns/100m |
18 |
Transmission Properties
FREQ mHz |
maximum Attenuation dB/100m |
minimum NEXT dB |
minimum PSNEXT dB |
minimum ELFEXT dB/100m |
minimum PSELFEXT dB/100m |
minimum RL dB |
0.772 |
1.8 |
76.0 |
74. |
70.0 |
67.0 |
— |
1 |
2.0 |
74.3 |
72.3 |
67.8 |
64.8 |
20.0 |
4 |
3.8 |
65.3 |
63.3 |
55.7 |
52.7 |
23.0 |
8 |
5.3 |
60.8 |
58.8 |
49.7 |
46.7 |
24.5 |
10 |
6.0 |
59.3 |
57.3 |
47.8 |
44.8 |
25.0 |
16 |
7.6 |
56.3 |
54.3 |
43.7 |
40.7 |
25.0 |
20 |
8.5 |
54.8 |
52.8 |
41.7 |
38.7 |
25.0 |
25 |
9.5 |
53.3 |
51.3 |
39.8 |
36.8 |
24.3 |
31.25 |
10.7 |
51.9 |
49.9 |
37.9 |
34.9 |
23.6 |
62.5 |
15.4 |
47.4 |
45.4 |
31.8 |
28.8 |
21.5 |
100 |
19.8 |
44.3 |
42.3 |
27.8 |
24.8 |
20.1 |
155 |
25.2 |
41.5 |
39.5 |
23.9 |
20.9 |
18.8 |
200 |
29.0 |
39.8 |
37.8 |
21.7 |
18.7 |
18.0 |
250 |
32.8 |
38.3 |
36.3 |
19.8 |
16.8 |
17.3 |
CONSTRUCTION PARAMETERS
Cable Code |
Conductor Diameter |
Diameter Over Insulation |
Pairs |
Screen |
Overall Diameter |
mm |
mm |
mm |
|||
CAT6 U/UTP |
0.57/0.58 |
1.02 |
4 |
Nil |
6.0 |
CAT6 F/UTP |
0.57/0.58 |
1.02 |
4 |
Overall Aluminum Tape Screen |
6.3 |
CAT6 SF/UTP |
0.57/0.58 |
1.02 |
4 |
Overall Aluminum Tape Screen & Copper Wire Braid |
6.6 |